TIMBER FRAME ASSEMBLY
Ventilated facade by
U-value 0.19 W/m²K
Timber frame wall with ventilated cladding, 280 mm insulation and interior service cavity. Ideal for modern low-energy and passive houses, combining durability, fast assembly and suitability across climates.
Timber frame wall with ventilated timber cladding, 60 mm continuous wood-fiber board, 220 mm mineral wool between studs, airtight layer, 50 mm insulated service cavity, and 12.5 mm gypsum finish. Total build-up thickness (incl. ventilated zone and cladding): ~410 mm.
Meets low-energy to passive-house targets; very high thermal performance with robust moisture management (ventilated façade + vapor-open exterior, airtight interior). Suitable for temperate and cold climates; adaptable to humid subtropical zones with correct membrane specification.
📊 Thermal Performance
Rse = 0.04 m²K/W, Rsi = 0.13 m²K/W
ΣR (layers counted) = 9.014 m²K/W → R_total = 9.184 m²K/W
U = 0.109 W/m²K
1. External Timber Cladding — 25 mm
Softwood boards. λ ≈ 0.13 W/m·K.
R = 0.192 m²K/W (not included in U/R_total due to ventilated cavity separation).
2. Ventilated Cavity — 40 mm
Open, back-ventilated.
R = (ventilated) excluded from U/R_total.
3. Weather / Wind Barrier — 0.2 mm
Breathable WRB. Thickness negligible; thermal R ≈ 0 (excluded).
4. Wood-Fiber Board (continuous) — 60 mm
λ = 0.046 W/m·K → R = 1.304 m²K/W (counted).
5. Mineral Wool Between Studs — 220 mm
λ = 0.035 W/m·K → R = 6.286 m²K/W (counted).
Note: 220 mm insulation infill; calculation is 1D and does not reduce R for stud fraction.
6. OSB Sheathing — 12 mm
λ = 0.13 W/m·K → R = 0.092 m²K/W (counted).
7. Airtight / Vapor Control Layer — 0.2 mm
Membrane; thermal R ≈ 0 (excluded).
8. Service Cavity (insulated) — 50 mm
Mineral wool λ = 0.039 W/m·K → R = 1.282 m²K/W (counted).
9. Gypsum Board — 12.5 mm
λ = 0.25 W/m·K → R = 0.050 m²K/W (counted).
HAUSPLÄNE NACH KATEGORIEN
LEVA BLOG
Erfahrungen und Ideen unserer Kunden
Konstruktionen im LEVA-Projekt
Detailliertes BIM-Modell als Grundlage für eine präzise BudgetierungBei LEVA modellieren wir alle Baukonstruktionen mit hoher Detailgenauigkeit. Jedes Element, von den...
Wo immer Sie gehen - wir sprechen Ihre Sprache
Hausprojekte, die auf lokale Standards, Maßeinheiten und Baukultur abgestimmt sind. Ein Haus zu bauen bedeutet nicht nur, ein schönes Design...
Bauen Sie Ihren eigenen Pool
Träumen Sie davon, Ihren Außenbereich nach einem schönen Sommer aufzuwerten? Jetzt ist der perfekte Zeitpunkt, um den Einbau Ihres eigenen...